• Bosch corporate
 

Chimney Hoods

> Home
How to install your chimney hoods
For recirculation mode installation
1. The appliance comes with a recirculating kit and charcoal filter(s).
2. The appliance has to be fitted with the charcoal filter(s) to remove odour.

For ducted mode installation

3. Refer to instruction manual on installation steps for recirculating kit.
  1. Pipe is bent immediately at the exhaust opening. Leave a minimum distance of 30cm between exhaust opening and the first bend.
  2. There are more than 2 bends on the pipe duct with 1 bending at a sharp 90° angle. Ensure that there is only 1 bend and choose a gentler 45° angle.
  3. The pipe duct is too long. Keep it as short as possible.
  4. The inner duct is rough and uneven. Choose a surface that is even and smooth.
  1. The duct design is narrow at certain parts. Ensure that the duct design is as wide as possible for optimal air flow.
  2. There are more than 2 bends on the pipe duct with 1 bending at a sharp 90° angle. Ensure that there is only 1 bend and choose a gentler 45° angle.
  3. For the wall box, keep the opening between lamella wide and avoid using micro mesh to reduce back pressure.
Preparing the unit for installation
  • Install the cooker hood in a dry place and avoid direct sunlight.
  • Always mount the cooker hood over the centre of the hob.
  • Maintain the required minimum distance between the hob and hood.
AB
≧550mm≧650mm
Example
Hood:DWB097E50B
Domino Hob:PIB375FB1E (Induction Hob)
PRB326B70E (Gas Hob)
Preparing the unit for installation

Channel extentions

Technical Details
  • Each cooker hood is equipped with an adjustable cover. The adjustable hood is installed in the decorative cover, which may be drawn upwards to cater the installation height.
  • Please refer to the dimensions shown in the table below before using the adjustable cover.
  • The adjustable cover is fixed on the wall by using brackets and screws.
TypeAB
Ducted≧954mm500mm
Recirculation1064mm500mm
TypeCD
Ducted300mm126mm
Recirculation300mm126mm
 
Online Survey